H-Flow High-Pressure Pump H80-4S
Product Description
The H-Flow High-Pressure Pump H80-4S is a high-capacity, robust pump engineered for industrial, commercial, and agricultural applications. Powered by a 5HP motor, this pump delivers reliable performance and exceptional efficiency for demanding environments requiring consistent water flow and pressure.
###
H-Flow High-Pressure Pump H80-4S
Cast Iron / Stainless Steel – 80 GPM – 4 Stage – 5 HP / 1 Phase
| Technical Specifications | |
|---|---|
| Model | H-Flow High-Pressure Pump H80-4S |
| Nominal Flow Rate | 80 GPM |
| Stages | 4 |
| Motor RPM | 3500 RPM |
| Motor Frame | NEMA JM Frame Motor (C-Face) |
| HP Rating | 5 HP |
| Phase / Hertz | 1 PH / 60 Hz |
| Inlet | 1½″ FNPT |
| App. Dimensions (A x B) | 19.70″ x 12.97″ |
| App. Weight (lb) | 141 |
###
Construction & Design Features
| Component | Description |
|---|---|
| Inlet / Motor Bracket | Cast Iron |
| Discharge Housing | Steel |
| Pump Housing | 304 Stainless Steel Tubing |
| Impellers | Noryl |
| Diffusers | Noryl |
| Wear Rings | 316 Stainless Steel |
| Shaft & Coupling | 316 Stainless Steel / 415 Stainless Steel |
| Shaft Bearing Sleeve | 316 Stainless Steel |
| Shaft Bearing | Bronze |
| Mechanical Seal | Carbon/Ceramic |
| Mechanical Seal Spacer | 416 Stainless Steel |
| O-Rings | Buna-N |
###
Installation Instructions
-
Preparation:
- Inspect the pump for any damage and verify that all components are included.
- Ensure the motor voltage matches the power supply specifications.
- Check the alignment of the pump and motor before installation.
-
Foundation:
- Mount the pump on a flat, stable surface to reduce vibrations during operation.
- Secure the pump using anchor bolts to ensure stability.
-
Piping Connections:
- Connect suction and discharge pipes using appropriate gaskets and seals.
- Support the piping to prevent stress on the pump connections.
- Install a check valve and isolation valve on the discharge side for operational control.
-
Priming the Pump:
- Fill the pump casing with liquid to ensure proper priming before starting.
- Use the vent valve to eliminate trapped air in the pump casing.
-
Electrical Wiring:
- Wire the motor according to local electrical codes and safety standards.
- Ensure the motor is properly grounded for safe operation.
- Verify that the motor rotation matches the direction indicated on the pump casing.
-
Startup:
- Fully open the suction and discharge valves before starting the pump.
- Start the motor and observe the pump for any irregularities.
- Check for leaks, vibrations, or unusual noises during startup.
-
Final Adjustments:
- Adjust the flow and pressure as needed using the discharge valve.
- Avoid throttling the suction side to maintain pump efficiency.
-
Regular Maintenance:
- Periodically inspect the pump and motor for wear or damage.
- Lubricate bearings and other components as per the manufacturer’s recommendations.
###
Shopping information
Product details & availability
Review the listed price, specifications and description. Choose an available variant before adding the item to your cart.
Shipping information
Shipping options and charges are confirmed during checkout when available for the selected item and destination.
Shipping policyReturns
Review the store refund policy before purchasing. Product-specific limitations remain as stated on the product listing.
Refund policyQuestions?
Contact Hot Spot Liquidators for help with a product or order.
contact@hotspotliquidators.com 1-844-946-8776